NPVA-110 is a 160L pulse vacuum autoclave used for advanced laboratory sterilization. It removes air using vacuum pulses and uses pressurized steam to sterilize instruments, glassware, liquids, and biohazardous materials, including wrapped and porous loads.
It sterilizes laboratory materials by:
Removing air using multi-vacuum pulses
Allowing deep steam penetration
Killing microorganisms under controlled pressure and temperature
It is designed for pharmaceutical, clinical, and research sterilization workflows.
NPVA-110 works in three controlled stages:
Air Removal Phase – Vacuum pulses eliminate trapped air
Steam Exposure Phase – High-pressure saturated steam enters chamber
Sterilization Phase – Controlled heat and pressure ensure complete microbial destruction
This ensures uniform sterilization even for complex and wrapped loads.
Multi-vacuum pulse sterilization system
High-efficiency steam penetration
Fully programmable sterilization cycles
Digital touch control interface
Supports liquids, porous, and wrapped loads
USP, ISO 17665, GMP compliant operation
Safety interlocks and overpressure protection
NPVA-110 is ideal for:
Pharmaceutical manufacturing labs
Biotechnology research facilities
Hospital sterilization units
Clinical and diagnostic laboratories
Surgical and laboratory instruments
Glassware and containers
Culture media and reagents
Biohazardous waste
Wrapped and porous materials
Liquid systems (aqueous systems)
A pulse vacuum autoclave is preferred because:
It removes air before sterilization begins
Ensures deeper steam penetration
Sterilizes wrapped and porous loads effectively
Provides better compliance for regulated industries
Chamber Volume: 160 L
Temperature Range: 105–135°C
Pressure Range: 0.1–2.1 bar
Cycle Time: 10–120 minutes
Display: Digital touch panel
Power Supply: 220V AC, 50Hz
Weight: ~220 kg
Automatic door interlock system
Overpressure protection
Real-time temperature monitoring
Cycle interruption safety control
USP Sterilization Guidelines
ISO 17665 Compliance
GMP Laboratory Standards
Q1. What is NPVA-110 used for?
It is used for sterilizing laboratory instruments, liquids, and biohazardous waste using vacuum-assisted steam sterilization.
Q2. Can NPVA-110 sterilize liquids?
Yes, it supports controlled liquid sterilization cycles.
Q3. What makes it different from gravity autoclave?
It removes air using vacuum pulses, ensuring deeper and more uniform sterilization.
Q4. Is NPVA-110 suitable for wrapped loads?
Yes, it is specifically designed for wrapped and porous materials.
Q5. What standards does it follow?
It complies with USP, ISO 17665, and GMP standards.
NPVA-110 is a 160L pulse vacuum autoclave designed for laboratory sterilization of instruments, glassware, liquids, and biohazardous materials. It uses multi-vacuum pulse technology to remove air and ensure deep steam penetration for wrapped and porous loads under USP, ISO, and GMP standards.
Which autoclave is best for 160L lab sterilization?
How does pulse vacuum autoclave work?
Is NPVA-110 suitable for pharmaceutical labs?
What is the difference between gravity and vacuum autoclave?
Compared to NPVA-109, NPVA-110 offers:
Larger chamber capacity (160L vs 140L)
Higher load handling capability
Better workflow efficiency for medium-high volume labs
NPVA-110 is designed for laboratories requiring high-capacity, compliant, and deep-penetration sterilization for complex and regulated workloads.