Any Query ?
Linear Pipette Stand NLPS-100
Linear Pipette Stand NLPS-100 offers a holding capacity of 5 to 6 pipettes for efficient storage. It is equipped with individual slots for each pipette, ensuring their secure protection. Our unit efficiently holds and organizes pipettes for the flexible and smooth functioning of experiments. It keeps pipettes upright, preventing contamination from benches and tables when not in use. It can accommodate different types of pipettes for enhanced versatility.
Pipette Holding Capacity | 5 to 6 |
Material | Plastic |
Colour | Blue + white |
Dimensions | 190 × 142 × 276 mm |
Packaging Dimensions | 320 × 140 × 45 mm |
Net Weight | 0.265 kg |
Gross Weight | 0.4 kg |
Linear Pipette Stand is used for organizing and securely storing pipettes. It is widely used in molecular biology, pharmaceutical industries, biotechnology, and research laboratories.
Labnics Multi-Channel Pipettes feature an ergonomic design for comfortable one-handed operation. Their large central control buttons and independent tip ejection enhance usability. They include color-coded tips for easy selection and accuracy. Their durable construction ensures resistance to corrosion and high temperatures. These pipettes can be fully sterilized and provide easy calibration technology. Our Multi-Channel Pipettes deliver precision and reliability for all your laboratory needs.
Volume Range | 100 µl, 500 µl, 1000 µl, |
Minimum Increment | ± 1 µl |
Systematic Error | 100 µl: ± 3.00%<br/> 500 µl: ± 1.00%<br/> 1000 µl: ± 0.60% |
Accuracy | 100 µl: ± 3 µl<br/> 500 µl: ± 5 µl<br/> 1000 µl: ± 6 µl |
No. of channels | 8 |
Volume Range | 0.5 to 10 µL |
Large Increment | 10/5/1 µL |
Accuracy | 1.6/2/8 % |
No. of channels | 8 |
Volume Range | 5 to 50 µL |
Large Increment | 50/25/5 µL |
Accuracy | 0.8/1.4/6 % |
No. of channels | 8 |
Volume Range | 10 to 100 µL |
Large Increment | 100/50/10 µL |
Accuracy | 0.8/0.6/4 % |
No. of channels | 8 |
Volume Range | 20 to 200 µL |
Large Increment | 200/100/20 µL |
Accuracy | 0.8/1.4/4 % |
No. of channels | 8 |
Volume Range | 30 to 300 µL |
Large Increment | 300/150/30 µL |
Accuracy | 0.6/1.2/3 % |
No. of Channels | 12 |
Volume Range | 0.5 to 10 µL |
Large Increment | 10/5/1 µL |
Accuracy | 1.6/2/8 % |
No. of Channels | 12 |
Volume Range | 5 to 50 µL |
Large Increment | 50/25/5 µL |
Accuracy | 0.8/1.4/6 % |
No. of Channels | 12 |
Volume Range | 10 to 100 µL |
Large Increment | 100/50/10 µL |
Accuracy | 0.8/0.6/4 % |
No. of Channels | 12 |
Volume Range | 20 to 200 µL |
Large Increment | 200/100/20 µL |
Accuracy | 0.8/1.4/4 % |
No. of Channels | 12 |
Volume Range | 30 to 300 µL |
Large Increment | 300/150/30 µL |
Accuracy | 0.6/1.2/3 % |
Labnics Pipette Stand efficiently stores and organizes micropipettes, enhancing accessibility. They are compatible with a wide range of pipette series, ensuring versatile use. These units feature a durable construction for long-lasting performance. They include a freely rotating design that allows for easy access, thereby enhancing workflow efficiency. Our pipette holders are tool-free and interchangeable for effortless adaptability for various pipette types.
Design | Rotatable stand |
Capacity | Six single or multi-channel pipettes |
Interchangeability | Tool-free, interchangeable pipette holders |
Compatibility | Holds 6 Eppendorf pipettes |
Labnics Adjustable Volume Pipettes boast a variable volume range and facilitate precise liquid handling. These pipettes allow users to easily select the desired volume, providing flexibility for tasks ranging from micro-sampling to larger liquid transfers. They feature an ergonomic design that ensures comfortable handling, significantly reducing hand fatigue during extended use. Our pipettes have an easy volume adjustment mechanism with a dial or push-button for efficient dispensing and quick settings. Their compatibility with standard pipette tips ensures a secure and leak-proof fit for reliable liquid transfer. Equipped with a digital display, these pipettes clearly show the set volume, enhancing usability and precision. Additionally, they are calibrated to meet international standards, ensuring consistent accuracy in results.
Volume range | 0.5-10µl |
Test volume | 10µl 5µl 1µl |
Micropipette tip | 10µl |
Increment | 0.1µl |
Volume range | 2-20µl |
Test volume | 20µl 10µl 2µl |
Micropipette tip | 200µl |
Increment | 0.5µl |
Volume range | 5-50µl |
Test volume | 50µl 25µl 5µl |
Micropipette tip | 200µl |
Increment | 0.5µl |
Volume range | 10-100µl |
Test volume | 100µl 50µl 10µl |
Micropipette tip | 200µl |
Increment | 1µl |
Volume range | 20-200µl |
Test volume | 200µl 100µl 20µl |
Micropipette tip | 200µl |
Increment | 1µl |
Volume range | 100-1000µl |
Test volume | 1000µl 500µl 100µl |
Micropipette tip | 1000µl |
Increment | 5µl |
Volume range | 1000-5000µl |
Test volume | 5000µl 2500µl 1000µl |
Micropipette tip | 5000µl |
Increment | 50µl |
Volume range | 2-10ml |
Test volume | 10ml 5ml 2ml |
Micropipette tip | 10ml |
Increment | 0.1ml |
Volume Range | 10-100μL | ||||
Increment | 1μL | ||||
Test Volume | 100μL 50μL 10μL | ||||
Maximum permissible systematic error (Inaccuracy) |
|
No. of Channels | 1 |
Volume Range | 0.1 to 2.5 μL |
Increment | 0.05 μL |
Test Volume | 2.5 μL, 1.25 μL, 0.25 μL |
Volume Range | 1000 to 10000 μL |
Increment | 100μL |
Test Volume | 10000μL, 5000 μL, 1000μL |
Systematic Error | ± 60μL, ± 60μL, ± 30μL<br> ±0.60%, ±1.20%, ±3.0% |
Our Fixed Volume Pipette precisely delivers a specific, predetermined volume for accurate results. They feature an ergonomic design that ensures comfortable handling during extended use, reducing hand fatigue and enhancing the user experience. The easy push-button operation allows for efficient and reliable liquid dispensing. Our pipettes are compatible with standard pipette tips, guaranteeing a secure and leak-proof fit for dependable liquid transfer. They are crafted from high-quality, autoclavable materials that are durable and resistant to chemical corrosion, ensuring longevity. Additionally, they are easy to calibrate, low-maintenance, and offer accuracy in liquid handling for various applications.
Volume Range | 10 µl |
Test volume | 10 µl |
Micropipette tip | 10 µl |
Increment | 0.08 µl |
Volume Range | 100 µl |
Test volume | 100 µl |
Micropipette tip | 200 µl |
Inaccuracy | 0.8 μl |
Volume Range | 100µl |
Test volume | 100 µl |
Micropipette tip | 200 µl |
Inaccuracy | 0.5 μl |
Volume Range | 20 µl |
Test volume | 20 µl |
Micropipette tip | 200 µl |
Inaccuracy | 0.12 μl |
Volume Range | 1000 μL |
Test Volume | 1000μL |
Systematic Error | ± 3μL<br> ±0.3% |
Random Error | ±0.2μL<br> ±0.2% |