WhatsApp
Product1
Product2
Product3
Tabletop Autoclave NTTA-100

Tabletop Autoclave NTTA-100

Tabletop Autoclave NTTA-100 is a tabletop steam sterilizer with an automatic pressure-temperature controller. These front-loading autoclaves combine of high temperature and pressure to bring about decontamination and sterilization of biological waste, culture media, instruments and lab ware. The inner chamber is a highly durable stainless steel with an installed electric heater for more efficient steam production and advanced vacuum for enhanced drying of discarded material. It is user-friendly and play important role in sterilization procedures across various Hospitals, Pharmaceutical companies, Biopharma and Microbiology laboratories etc.


$3,025.00

Catalog

Specifications

Capacity 20 L
Body 304 Stainless-steel
Type Front loading
Chamber volume ∮ 250 × 420 mm
Working pressure 0.22 Mpa
Working temperature 134°C
Maximum working pressure 0.23 Mpa
Heat fluctuation ≤ ± 1°C
Timer range 0-99 min
Temperature adjust range 105°C - 134°C
Power 1.5 kW ; AC 110/220V, 50/60 Hz
Loading shelf material Stainless-steel
No. of shelves 3
Shelf dimension 340 × 200 × 30 mm
Display LED
Overall Dimension 480 × 480 × 380 mm
Packing Dimension 700 × 580 × 500 mm
Net Weight 40 kg
Gross Weight 43 kg

Features

  • Inner stainless-steel chamber
  • Lock system for door safety
  • Digital display and touch-type key
  • Inner circulation of steam water with no steam discharge
  • Automatic shutdown after completion of sterilization

Applications

  • Employed for sterilization in microbiological, pharmaceutical, clinical and hospital labs.

Ask Expert

FAQ for Tabletop Autoclave NTTA-100

1: What safety features does the Tabletop Autoclave NTTA-100 offer?

The Tabletop Autoclave includes a secure door locking system that ensures user safety during operation. The autoclave also automatically shuts down after the sterilization cycle is complete, reducing manual intervention and enhancing safety.

2: How does the Tabletop Autoclave ensure effective sterilization?

The Tabletop Autoclave operates at a high working temperature of 134°C and a pressure of 0.22 MPa, delivering reliable sterilization of biological waste, labware, and culture media. The built-in electric heater and stainless-steel chamber optimize steam generation and heat distribution.

3: Is it easy to operate and monitor the Tabletop Autoclave NTTA-100?

Our Tabletop Autoclave features a digital LED display with touch-type controls, allowing clear monitoring and simple operation. The interface is intuitive, making it accessible even to users with minimal training.

4: Does the Tabletop Autoclave NTTA-100 release steam externally during operation?

No, the Tabletop Autoclave uses the inner circulation of steam water with no steam discharge, maintaining a clean and safe work environment. This feature also helps in conserving energy and improving overall efficiency.

5: How often should the Tabletop Autoclave be cleaned?

Regular cleaning is recommended after every few sterilization cycles to maintain optimal performance. The inner stainless-steel chamber should be wiped down to prevent residue buildup and contamination.

6: Is it easy to operate a Tabletop Autoclave?

Yes, our Tabletop Autoclave is designed with a digital control panel that simplifies operation and cycle monitoring. Most models come with preset sterilization programs that can be adjusted based on the material being sterilized. This makes the process convenient and user-friendly even for first-time users.

7: What safety features does the Tabletop Autoclave include?

The Tabletop Autoclave is equipped with multiple safety features such as over-temperature protection, pressure control systems, and secure door-locking mechanisms. These ensure that the unit operates safely and reduces any risk during the sterilization process. It also alerts when water levels are low to prevent dry running.

8: How fast is the sterilization process?

The Tabletop Autoclave offers rapid heating and efficient steam generation, which shortens the sterilization cycle time. This allows multiple batches of instruments to be processed within a short period. It’s especially useful in busy settings where quick turnaround is essential.

9: Is the Tabletop Autoclave durable and easy to maintain?

The inner chamber is typically made of stainless steel, which is corrosion-resistant and easy to clean. Routine maintenance, like descaling and wiping down surfaces, helps keep the unit in good working condition. Most models are designed for long-term use with minimal upkeep.


Tabletop Autoclave NTTA-100

Tabletop Autoclave NTTA-100

Related Models Of Tabletop Autoclaves

Labnics Tabletop Autoclave offers an automatic pressure-temperature control system for optimal sterilization conditions. They have an automatic shutdown mechanism that activates after the sterilization cycle. These autoclaves include a safety lock function for secure closure during operation. Our units feature a durable construction that ensures long-lasting and reliable performance. They have a user-friendly interface with digital displays and touch-type controls for easy handling.

Labnics © 2026. All Rights Reserved.
0