Any Query ?
Colorimeter NCC-100 is made with a full-waveband LED light source that ensures sufficient spectral distribution in the visible light range. Equipped with a silicon photodiode array sensor that has higher sensitivity to low light and a wider spectral response range. Designed with a flat grating and a true colour capacitive touch screen. The unit is made with ETC real-time calibration technology. It has an ergonomic design.
Optical Geometry | D/8(diffused illumination, 8-degree viewing angle), SCI mode |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source |
Spectrophotometric Mode | Flat Grating |
Senso | Silicon photodiode array (double row 24 groups) |
Wavelength Range | 400~700nm |
Semi band Width | 10nm |
Measured Reflectance Range | L:0~100; reflectivity: The reflectivity can be measured at 3 specific wavelengths specified by the user (default: 440nm, 550nm, 600nm) |
Measuring Aperture | Φ8mm |
Specular Component | SCI |
Color Space | CIE LAB, XYZ, Yxy, LCh |
Color Difference Formula | ΔE*ab, ΔE*00 |
Observer Angle | 10° |
Illuminant | Chromaticity value: MAV/SCI, within ΔE*ab 0.08 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Displayed Data | Reflectivity (the user specifies the reflectivity at 3 specific wavelengths), Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
Displayed Accuracy | Display 0.1, storage 0.01 |
Measuring Time | About 1.5s |
Repeatability | Chromaticity value: MAV/SCI, within ΔE*ab 0.08 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.4 (Average for 12 BCRA Series II color tiles) |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Stabilizer cross position |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB |
Data Storage | Standard 500 Pcs, Sample 10000 Pcs |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Dimension (L× W × H) | 81× 71 × 214 mm |
Weight | 460 g |