Benchtop Multi-Parameter Meter NBMM-102 measures pH within a range of -2.000 to 20.000 with an accuracy of ±0.002. It offers automatic and manual temperature compensation for accurate results. This meter can store up to 1000 data sets per parameter, adhering to GLP compliance standards. Our unit offers automatic barometric adjustment for precise dissolved oxygen measurements. It features a 7.0-inch high-contrast LCD touchscreen for easy operation.

Specifications
Test Parameters pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal. /DO Saturation)
pH Range: -2.000 to 20.000 pH
Resolution: 0.1, 0.01, 0.001 pH
Accuracy: ±0.002 pH
Calibration Points: Up to 6
Standard Customization: Yes
Calibration Reminder: Yes
Slope Limit: Yes
Calibration Solutions NIST, GB, DIN, USA, MERK, JIS buffers
mV/ORP Range: -2000.00 to 2000.00 mV
Resolution: 0.1, 0.01 mV
Accuracy: reading whichever is greater
Calibration Points: 1 custom point (relative mV)
EH ORP Mode: Yes
pX Range: -2.000 to 20.000 pX
Resolution: 0.1, 0.01, 0.001 pX
Accuracy: ±0.002 pX
Calibration Points: Up to 6
ISE Range: 1.000e-9 to 9.999e+9
Units: mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Resolution: Up to 4 significant digits
Accuracy: ±0.3%
Calibration Points: Up to 6
Conductivity Range: 0.000 μS/cm to 2000 mS/cm
Resolution: 0.001 μS/cm minimum, varies with range selection
Accuracy: ±0.5% FS
Calibration Points: Up to 5
Settable parameters: Cell constant, reference temperature, temperature compensation coefficient, and TDS factor
Standard Recognition: 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm
Reference Temperature: 5, 10, 15, 18, 20, 25 ºC
Calibration Reminder: Yes
Resistivity Range: 5.00 Ω·cm to 100.0 MΩ·cm
Resolution: 0.01 Ω·cm minimum
Accuracy: ±0.5% FS
TDS Range: 0.000 to 1000 ppt
Resolution: 0.001 ppm minimum, varies with range selection
Accuracy: ±0.5% FS
Salinity Type Type: NaCl
Range: 0.0 to 80.0 ppt
Resolution: 0.1 ppt
Accuracy: ±1 ppt
Dissolved Oxygen Concentration (Polarographic) Range: 0.00 to 99.99 ppm
Resolution: 0.01 ppm
Accuracy: ±0.10ppm, 0.00 to 50.00ppm
±0.50ppm, 50.0 to 99.99ppm
Calibration Points: Air-saturated water or zero point
Auto barometric pressure compensation
Selectable pressure unit: kPa, mbar, Torr, Atm.
DO Calibration Reminder: Yes
% Saturation (Polarographic) Range: 0.0 to 600%
Resolution: 0.10%
Accuracy: ±2.0%
Temperature Range: -10 to 135 ℃, 14 to 275 °F
Resolution: 0.1
Accuracy: ±0.1
Temperature Compensation ATC, MTC
Measurement Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Measurement Reading Prompts Reading, Stable, Locked
Data Storage 1000 Groups
GLP Features Yes
Log Management Yes
pH Electrode Input BNC(Q9)
DO with Temp. Probe Input 4-pin aviation connector
Conductivity with Temp. Probe Input 5-pin aviation connector
Outputs USB: USB 2.0 flash memory device, PC, scanner
RS 232: Printer, auto-sampler
Backlight Yes
Auto Shutdown 1 to 60 min, off
Date and Time Yes
Power AC Adapter, 100-240V AC input, DC 24V output
Dimensions 220 × 195 × 68 mm
Weight 950g (2.09 lb.)
Features
Applications

Benchtop Multi-Parameter Meter measures various parameters such as pH, dissolved oxygen, and conductivity. It is commonly used in environmental monitoring, water quality testing, and laboratory analysis.

Buy Now

Multi-Parameter Meter (Benchtop)

Labnics Benchtop Multi-Parameter Meter offers both automatic and manual temperature compensation, ensuring precise measurements. They include data analysis functions for detailed examination and interpretation of results. Our units include a touchscreen for simple and intuitive operation. These meters feature automatic electrode diagnosis to continuously monitor electrode conditions. They offer a data storage function for saving and managing measurement records.


BOD Meter NBOD-102

Measurement range 0-4000mg/L
Measuring error ±10%
Cycle length 5 days
Measure amount 6

BOD Meter NBOD-101

Measuring range 0 to 4000 mg/L
Measuring error ±10%
Resolution 2 mg/L
Cycle length 1-5 days
BOD Meter NBOD-100
Measurement range 0 to 4000mg/L
Measuring error ±10%
Cycle length 5days
Measure amount 6
BOD Meter NBOD-103
Measuring Principle Manometric; mercury-free; electronic pressure sensor
Measuring Range 0 to 40, 0 to 80, 0 to 200, 0 to 400, 0 to 800, 0 to 2000, 0 to 4000 mg/l
Measurement Time User-selectable, between 1 and 28 days
Storage Interval Hourly (1st day)<br/> Every 2 hours (2nd day)<br/> Once daily (3rd - 28th day)

COD Analyzer NCA-100

High COD Range 20 to 10000mg/L
Low COD Range 2 to 150mg/L
Accuracy for COD < 50mg/L ≤ ±5%
Accuracy for COD > 50mg/L ≤ ±3%

Benchtop COD Digester NBCD-100
Digestion capacity 9 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 100 mm
Digestion temperature 20°C - 200°C
Benchtop COD Digester NBCD-101
Digestion capacity 16 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 150 mm / ф20mm × 150 mm
Digestion temperature 45°C - 190°C

Conductivity Controller Analyzer NCCA-100

Model no NCCA-100
Measuring range k= 1 0~2000μS/cm
Resolution 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm
Accuracy ± 2.0 %(FS)

Portable Conductivity Meter NCM-100
Conductivity specifications:- Conductivity range 0.000µS/cm ~ 1000mS/cm
Conductivity resolution 0.001µS/cm
Conductivity accuracy ± 1.0% (FS)
Resistivity specifications:- Resistivity range 5.00Ωcm~ 100.0MΩcm

Benchtop Dissolved Oxygen Meter NDOM-100

Dissolved Oxygen Range 0.00-20.00mg/L
Dissolved Accuracy ±0.2mg/L
Dissolved Resolution 0.01 mg/L
Saturation of Oxygen Range 0.0-200.0%

Dissolved Oxygen Sensor NOS-100

Dissolved Oxygen Range 0~20 mg/L or 0~200 %
Dissolved Oxygen Sensor Optical DO sensor
Dissolved Oxygen Accuracy 0.01
Dissolved Oxygen Sensor Drift <1 % per year
Dissolved Oxygen Sensor NOS-101
Dissolved Oxygen Range 0 to 20mg/L or 0 to 200%
Sensor Optical DO sensor
DO Accuracy 0.03
Dissolved Oxygen Sensor Drift <1% per year

Portable Fluoride Analyzer NPFA-100

Ion Concentration Range 0.02 to 1900 ppm
Ion Concentration Resolution 0.001, 0.01, 0.1, 1
Ion Concentration Accuracy ±0.5% F.S
Calibration Solutions 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000

Labnics Multiparameter Conductivity Meter are designed to measure multiple parameters for comprehensive analysis. They feature imported sensors and advanced optical system for precise measurement. They offer various conductivity ranges for accurate sample readings. They are constructed with durable materials to withstand harsh environments. Our meter is ideal for water quality analysis, environmental monitoring and industrial processes.

Portable Multiparameter Conductivity Meter NPMCM-100

pH
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Conductivity
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS
Range 0to100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)
Multiparameter Conductivity Meter NPMCM-200
Absorbance Detection Range 0 to 3Abs
Absorbance Resolution 0.001Abs
Optical Path Stability ≤ ±0.005Abs/30min
Operation Repeatability ≤ ±0.01Abs

Portable PH Conductivity Meter NPCM-100

pH Range 2.000~20.000 pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, selectable
Calibration Points 1 to 5 points

PH Conductivity Meter NPCM-101

pH Measuring Range - 2.00 to 19.99 pH
pH Resolution 0.1/0.01 pH
pH Accuracy Meter: ±0.01 pH; Overall: ±0.02 pH
Input Current ≤ 2×10⁻¹² A

Portable PH Conductivity Meter NPCM-102

Measuring Parameters Conductivity, temperature
Measuring Conductivity Range 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Measuring Conductivity Resolution 0.001, 0.01, 0.1, 1
Measuring Conductivity Accuracy ±0.5% F.S.

PH Controller Analyzer NPCA-100
Model no NPCA-100
Detection method Electrode method
Measuring range 0 ~ 14 pH; normal temperature (0 ~ 80 ℃)
Resolution 0.01ph

Benchtop PH Meter NBPM-201

pH measuring range 0.00 ~ 14.00 pH
pH resolution 0.01 pH
pH accuracy ± 0.01 pH
Temperature measuring range 0°C~100°C

Benchtop PH Meter NBPM-200

pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Benchtop PH Meter NBPM-202
Measuring Parameters pH/mV
pH Measurement Range -2.00 to 18.00 pH
pH Measurement Resolution 0.01 pH
pH Measurement Accuracy ± 0.01 pH

PH ORP Meter NPOM-100

Model name NPOM-100
Measuring Range -2.00~20.00pH
Display Resolution 0.01pH
Measurement Accuracy ± 0.01pH

Turbidity Meter NTM-100

Measurement range 0~1100 NTU, 0~275 EBC, 0~9999 ASBC
Measurement accuracy ±2% of reading (0~500 NTU), ±3% (501~1100 NTU)
Measurement resolution 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU)
Sample volume 30 ml
Turbidity Meter NTM-101
Turbidity Range 0.000 to 20.00 NTU, 20.01 to 200.0 NTU, 200 to 2000 NTU, 2001 to 4000 NTU
Accuracy ≤ ±6%
Resolution 0.01NTU, 0.1NTU, 1NTU
Repeatability ≤ 0.5%

Bench-top Conductivity Meter NBCM-100

Parameters Conductivity, Temperature, Resistivity, TDS, and Salinity
Conductivity mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>0.000 µS/cm to 3000 mS/cm</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.001 µS/cm minimum, changes with ranges</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px>± 0.5% FS</td> </tr> <tr> <td style=min-width:50px>Reference Temperature </td> <td style=min-width:50px>5, 10, 15, 18, 20, 25 ºC</td> </tr> <tr> <td style=min-width:50px>Calibration Points </td> <td style=min-width:50px>Up to 5</td> </tr> <tr> <td style=min-width:50px>Standard Recognition </td> <td style=min-width:50px>146.5 µS/cm, 1408 µS/cm, 12.85 mS/cm, 111.3 mS/cm</td> </tr> </table>
Resistivity Mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>5.00 Ω ·cm to 100.00 M Ω ·cm</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.01 Ω ·cm minimum</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px> ± 0.5% FS</td> </tr> </table>
TDS Mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>0.000 mg/L to 1000 g/L</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.001 ppm minimum, changes with range</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px>±0.5% FS</td> </tr> </table>

Multi-Purpose PH Tester NMPT-100

pH Range (-1.00) to 15.00
pH Accuracy ±0.01
pH Calibration Points 1 to 3 points
pH Buffer Options pH 4.01/6.86/7.00/9.18/10.01

Multi-Parameter Water Quality Analyzer NMWA-100
COD Measurement Range 0-15000mg/L
Ammonia Nitrogen Measurement Range 0-160mg/L
Phosphorus Measurement Range 0-100mg/L
Nitrogen Measurement Range 0-150mg/L

Online Ion Meter NOIM-100

Measurement Range 0 to 35500mg/L(ppm)
Measurement Principle Ion electrode method
Resolution 0.01mg/L(ppm)
Basic Error ± 2.5%

Labnics Online Ozone Meter detects ozone levels accurately across a wide range of concentrations. They include manual and automatic temperature compensation modes for reliable results. These ozone meter comes with built-in alarm functions for immediate alerts on fluctuating values. They enable efficient and reliable data transfer, ensuring smooth integration with other systems. Our units feature a large screen display for clear and easy interpretation of results.

Online Ozone Meter NOOM-100
Measurement Range 0 to 20mg/L<br/> 0 to 20 ppm
Measurement Principle Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic Error ±1%F. S

Labnics Digital pH Meter includes 3-point calibration to ensure reliable and consistent pH measurements. They include a digital pH sensor for obtaining precise results. The replaceable pH electrode allows to change of the degraded electrode for easy maintenance. Their stable operation enhances to function without fluctuations, assuring accurate data. Our Digital pH Meter eliminates vibrations, for precise readings by minimizing errors.

Digital PH Meter NDPM-100

pH Range 0.00 to 14.00 pH
pH Accuracy ± 0.01 pH
pH Resolution 0.01 pH
Calibration Points Three points (4.00, 6.86, 9.18)

Labnics Water Activity Meter measures moisture levels accurately across a wide range of materials. They offer calibration capabilities that allow for easy adjustments to maintain accurate measurements. Our units feature an LCD for clear reading of measurement results. They provide efficient data transfer options for reliable connectivity, ensuring easy integration with other devices. These water activity meters have a print function for easy documentation of results.

Water Activity Meter NWAM-100

Measuring Water Activity Range 0 to 1.000 aw
Measuring Water Activity Accuracy ±0.012 aw (at 23℃ ± 5℃)
Operating Temperature Range -10℃ to 50℃
Relative Humidity 0 to 95%RH

Labnics Chlorine Analyzers are designed to provide accurate readings in many applications. They feature automatic temperature compensation, ensuring precise measurements across varying temperatures. Their portability allows for easy integration into various settings, offering flexibility. They include calibration capabilities for enhanced accuracy and reliable performance. Our units are built with durable materials for long-lasting reliability.

Portable Chlorine Analyzer NCLA-100
Measuring principle Constant voltage method
Measuring range 0 to 2.000mg/L; 0 to 20mg/l (HClO)
Resolution 0.001mg/L; 0.01mg/
Accuracy ±5%; ±0.05mg/L,±0.3℃