Benchtop Multi-Parameter Meter NBMM-100 is a laboratory apparatus designed for measurement of pH, conductivity, temperature, salinity, TDS etc of water and various industrial samples. It is equipped with built-in real-time clock that meets the GLP regulatory standards of any laboratory setting. It enables automatic temperature compensation for accurate display of reading value over the entire pH range and other parameters. The subsequent reminder alerts for calibration aids in maintaining the smooth functionality of a meter.

Specifications
pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
mV Range (-1999.9~1999.9) mV
mV Accuracy ±0.2mV
mV Resolution 0.1, 1mV, Selectable
mV Calibration Points 1 point (Only for Relative mV mode)
mV Measurement Modes Relative or absolute mV
Conductivity Range 0.01~20.00,200.0,2000µS/cm,20.00,200.0mS/cm
Conductivity Accuracy ±0.5% F.S
Conductivity Resolution 0.001,0.01,1, automatic
Conductivity Calibration Points 1 to 5 points
Conductivity Calibration Solutions 10µS/cm,84µS/cm,1413µS/cm,12.88mS/cm,111.8 mS/cm
Temperature Coefficient Linear(0.0~10.0%/°C) or pure water compensation
Cell Constant K=0.1,1,10 or custom
Reference Temperature 20°C or 25°C
TDS Range 0~10.00,100.0,1000ppm,10.00,100.0ppt(max 200ppt)
TDS Accuracy ±1%F.S
TDS Resolution 0.01,0.1,1, automatic
TDS factor 0.1~1.0(Default 0.5)
Salinity Range 0.00~80.00ppt,0.00~42.00psu
Salinity Accuracy ±1%F.S
Salinity Resolution 0.01
Measurement Modes Practical salinity(psu) or natural seawater(ppt)
Resistivity Range 0.00-20.00MΩ
Resistivity Accuracy ±1%F.S
Resistivity Resolution 0.01
General Temperature Compensation 0~100°C,32~212°F, manual or automatic
Stability Criteria Low or high
Calibration Due Alarm 1 to 31 days or off
Power Supply DC5V,AC 220V/50Hz
Overall Dimensions(L×W×H) 210×188×60 mm
Weight 1.5kg
Features
Applications

It has multidisciplinary applications in areas like research and development, water testing laboratories, sewage water treatment plant, brewing and wine industries, healthcare and clinical applications etc.

Standard Accessories

Accessories No Name
1 pH electrode
2 Temperature probe
3 pH buffer solutions (pH 4.0/7.00/10.01)
4 DC9V power adapter

Buy Now

Multi-Parameter Meter (Benchtop)

Labnics Benchtop Multi-Parameter Meter offers both automatic and manual temperature compensation, ensuring precise measurements. They include data analysis functions for detailed examination and interpretation of results. Our units include a touchscreen for simple and intuitive operation. These meters feature automatic electrode diagnosis to continuously monitor electrode conditions. They offer a data storage function for saving and managing measurement records.


BOD Meter NBOD-102

Measurement range 0-4000mg/L
Measuring error ±10%
Cycle length 5 days
Measure amount 6

BOD Meter NBOD-101

Measuring range 0 to 4000 mg/L
Measuring error ±10%
Resolution 2 mg/L
Cycle length 1-5 days
BOD Meter NBOD-100
Measurement range 0 to 4000mg/L
Measuring error ±10%
Cycle length 5days
Measure amount 6

COD Analyzer NCA-100

High COD Range 20 to 10000mg/L
Low COD Range 2 to 150mg/L
Accuracy for COD < 50mg/L ≤ ±5%
Accuracy for COD > 50mg/L ≤ ±3%

Benchtop COD Digester NBCD-100

Digestion capacity 9 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 100 mm
Digestion temperature 20°C - 200°C
Benchtop COD Digester NBCD-101
Digestion capacity 16 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 150 mm / ф20mm × 150 mm
Digestion temperature 45°C - 190°C

Conductivity Controller Analyzer NCCA-100

Model no NCCA-100
Measuring range k= 1 0~2000μS/cm
Resolution 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm
Accuracy ± 2.0 %(FS)

Portable Conductivity Meter NCM-100

Conductivity specifications:- Conductivity range 0.000µS/cm ~ 1000mS/cm
Conductivity resolution 0.001µS/cm
Conductivity accuracy ± 1.0% (FS)
Resistivity specifications:- Resistivity range 5.00Ωcm~ 100.0MΩcm

Benchtop Dissolved Oxygen Meter NDOM-100
Dissolved Oxygen Range 0.00-20.00mg/L
Dissolved Accuracy ±0.2mg/L
Dissolved Resolution 0.01 mg/L
Saturation of Oxygen Range 0.0-200.0%

Dissolved Oxygen Sensor NOS-100

Dissolved Oxygen Range 0~20 mg/L or 0~200 %
Dissolved Oxygen Sensor Optical DO sensor
Dissolved Oxygen Accuracy 0.01
Dissolved Oxygen Sensor Drift <1 % per year

Dissolved Oxygen Sensor NOS-101

Dissolved Oxygen Range 0 to 20mg/L or 0 to 200%
Sensor Optical DO sensor
DO Accuracy 0.03
Dissolved Oxygen Sensor Drift <1% per year

Portable Fluoride Analyzer NPFA-100
Ion Concentration
Range 0.02 to 1900 ppm
Resolution 0.001, 0.01, 0.1, 1, automatic
Accuracy ±0.5% F.S
Calibration Points 2 to 5 points
Calibration Solutions 0.001 / 0.01 / 0.1 / 1 / 10 / 100 /1000/10000
Measurements Units ppm, mg/L, mol/L, mmol/L
mV
Range (-1999.9 to 1999.9) mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Temperature
Range 0 to 105°C / 32 to 221°F
Resolution 0.1°C/°F
Accuracy ±0.5°C / ±0.9°F
Offset Calibration 1 point
Calibration Range Reading ±10°C/°F
Other
Temperature Compensation 0 to 100°C / 32 to 212°F, manual or automatic
Hold Function Manual / Auto-read measurement endpoint
Stability Criteria Low / High
Calibration Due Alarm 1 to 31 days or off
Auto-Power Off 10 / 20 / 30 minutes after last key pressed
Memory Stores up to 500 data sets
Output USB communication interface
Connector BNC, 3.5 mm jack socket
Display Custom LCD (80 × 60 mm)
Power Supply 3 × 1.5V AA batteries or 5V DC power adapter
Battery Life Approximately 150 hours without backlight
Environmental Conditions 0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions 170 × 85 × 30 mm
Weight 300g

Labnics Multiparameter Conductivity Meter are designed to measure multiple parameters for comprehensive analysis. They feature imported sensors and advanced optical system for precise measurement. They offer various conductivity ranges for accurate sample readings. They are constructed with durable materials to withstand harsh environments. Our meter is ideal for water quality analysis, environmental monitoring and industrial processes.

Portable Multiparameter Conductivity Meter NPMCM-100

pH
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Conductivity
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS
Range 0to100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)

Multiparameter Conductivity Meter NPMCM-200

Absorbance Detection Range 0 to 3Abs
Absorbance Resolution 0.001Abs
Optical Path Stability ≤ ±0.005Abs/30min
Operation Repeatability ≤ ±0.01Abs

Portable PH Conductivity Meter NPCM-100
pH Range 2.000~20.000 pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, selectable
Calibration Points 1 to 5 points

PH Controller Analyzer NPCA-100

Model no NPCA-100
Detection method Electrode method
Measuring range 0 ~ 14 pH; normal temperature (0 ~ 80 ℃)
Resolution 0.01ph

Benchtop PH Meter NBPM-201
pH measuring range 0.00 ~ 14.00 pH
pH resolution 0.01 pH
pH accuracy ± 0.01 pH
Temperature measuring range 0°C~100°C
Benchtop PH Meter NBPM-200
pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points

PH ORP Meter NPOM-100

Model name NPOM-100
Measuring Range -2.00~20.00pH
Display Resolution 0.01pH
Measurement Accuracy ± 0.01pH

Turbidity Meter NTM-100
Measurement range 0~1100 NTU, 0~275 EBC, 0~9999 ASBC
Measurement accuracy ±2% of reading (0~500 NTU), ±3% (501~1100 NTU)
Measurement resolution 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU)
Sample volume 30 ml
Turbidity Meter NTM-101
Turbidity Range 0.000 to 20.00 NTU, 20.01 to 200.0 NTU, 200 to 2000 NTU, 2001 to 4000 NTU
Accuracy ≤ ±6%
Resolution 0.01NTU, 0.1NTU, 1NTU
Repeatability ≤ 0.5%

Bench-top Conductivity Meter NBCM-100

Parameters Conductivity, Temperature, Resistivity, TDS, and Salinity
Conductivity mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>0.000 µS/cm to 3000 mS/cm</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.001 µS/cm minimum, changes with ranges</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px>± 0.5% FS</td> </tr> <tr> <td style=min-width:50px>Reference Temperature </td> <td style=min-width:50px>5, 10, 15, 18, 20, 25 ºC</td> </tr> <tr> <td style=min-width:50px>Calibration Points </td> <td style=min-width:50px>Up to 5</td> </tr> <tr> <td style=min-width:50px>Standard Recognition </td> <td style=min-width:50px>146.5 µS/cm, 1408 µS/cm, 12.85 mS/cm, 111.3 mS/cm</td> </tr> </table>
Resistivity Mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>5.00 Ω ·cm to 100.00 M Ω ·cm</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.01 Ω ·cm minimum</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px> ± 0.5% FS</td> </tr> </table>
TDS Mode <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>0.000 mg/L to 1000 g/L</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.001 ppm minimum, changes with range</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px>±0.5% FS</td> </tr> </table>

Multi-Purpose PH Tester NMPT-100
pH Range (-1.00) to 15.00
pH Accuracy ±0.01
pH Calibration Points 1 to 3 points
pH Buffer Options pH 4.01/6.86/7.00/9.18/10.01

Multi-Parameter Water Quality Analyzer NMWA-100

COD Measurement Range 0-15000mg/L
Ammonia Nitrogen Measurement Range 0-160mg/L
Phosphorus Measurement Range 0-100mg/L
Nitrogen Measurement Range 0-150mg/L

Online Ion Meter NOIM-100

Measurement Range 0 to 35500mg/L(ppm)
Measurement Principle Ion electrode method
Resolution 0.01mg/L(ppm)
Basic Error ± 2.5%

Labnics Online Ozone Meter detects ozone levels accurately across a wide range of concentrations. They include manual and automatic temperature compensation modes for reliable results. These ozone meter comes with built-in alarm functions for immediate alerts on fluctuating values. They enable efficient and reliable data transfer, ensuring smooth integration with other systems. Our units feature a large screen display for clear and easy interpretation of results.

Online Ozone Meter NOOM-100
Measurement Range 0 to 20mg/L<br/> 0 to 20 ppm
Measurement Principle Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic Error ±1%F. S

Labnics Digital pH Meter includes 3-point calibration to ensure reliable and consistent pH measurements. They include a digital pH sensor for obtaining precise results. The replaceable pH electrode allows to change of the degraded electrode for easy maintenance. Their stable operation enhances to function without fluctuations, assuring accurate data. Our Digital pH Meter eliminates vibrations, for precise readings by minimizing errors.

Digital PH Meter NDPM-100

pH Range 0.00 to 14.00 pH
pH Accuracy ± 0.01 pH
pH Resolution 0.01 pH
Calibration Points Three points (4.00, 6.86, 9.18)