Any Query ?
Multi-gas Analyzer NMA-230
Multi-gas analyzer NMA-230 is a portable multi-gas detector designed for measurement, analysis, monitoring and control of gas output. Equipped with four gas detector sensors for oxygen, combustibles, hydrogen sulfide and carbon monoxide. Built-in, high-power carbon film with self-priming pump with quick response facilitates easy sampling of gases present at lower atmospheric pressure. The Acrylonitrile – Butadiene- Styrene body shell is dust-proof, explosion-proof and water-proof and durable at low temperatures.
Sensor | Catalytic / Electrochemical / PID / Infrared sensor |
Sampling method | Pump suction type |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, and combustibles |
Measurement error | ≤ ± 5% FS |
Response time | ≤ 20 secs |
Charging time | ≤ 6h |
Operating humidity ( non-condensing ) | < 95% RH |
Operating temperature | ( -50 °C to 50 °C ) |
Display panel | LCD screen |
Data storage | 5000 values data record |
Alarm type | Acousto-optic vibration |
Body shell material | Acrylonitrile – Butadiene- Styrene polymer, slip silicone |
Battery life ( rechargeable ) | 8+ hours |
Power supply | 3.7 V Li, 2800 mAh battery |
Dimensions ( W x H x D ) | 175 x 76 x 48 mm |
Weight | 450 g |
Used for the measurement and analysis of gas output or leakage in ceramic, iron-steel industry, thermal treatment, electronic, agricultural, biochemical facilities for environmental pollution regulation
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | CO, O2, Cl2, SO2, O3, CO2, CH4, H2S, NH3, NO, NO2, H2, LEL, LPG, PID, EXP, CH4 (IR), C3H8 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | Non-dispersive infrared sensor |
Sampling method | Diffusion |
Detection range | CO2,CH4 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | O2, CH4, CO, H2S, SO2, Cl2, NH3, NO2, NO, H2, HCl, HCN, CH4, PID (VOCs), CO2, C3H8 and O3 |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Gas detected | Acetylene C2H2 |
Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
Data logger | 100,000 data sets can be stored, with a storage space limit of 5S |
Measuring range | 0 to 50 ppm |
Sensor | High sensitivity sensors |
Sampling method | Diffusion |
Detection range | CO, O2, Cl2, SO2, O3, CO2, CH4, H2S, NH3, NO, NO2, H2, LEL, LPG, PID, EXP, CH4 (IR), C3H8 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |