Microwave Digestion System NMDS-202
Microwave Digestion System NMDS-202 is an instrument used in sample preparation for superior trace elemental analysis. Equipped with variable frequency resonance microwave heating system, it prepares samples in less time than traditional methods and is therefore an instrument of choice for sample preparation. It also saves on usage of acid required for sample digestion and also retains the volatile elements. This instrument is used in labs to ensure accurate sample analysis and quick results.
Sample vessel | 40 / batch |
Vessel volume | 40 mL |
Microwave power | 0-3000W, adjustable |
Microwave frequency | 2450MHz |
Microwave leak | <5mw/ cm² |
Digestion method | Microwave heating |
Temperature range | 50°C-400℃ |
Temperature accuracy | ±0.3℃ |
Pressure control range | 0-10 Mpa |
Pressure accuracy | ± 0.01 Mpa |
Maximum pressure | 20 Mpa |
Vessel Pressure capacity | 20 Mpa |
Display | 7" LCD screen |
Control mode | Touch screen |
Power supply | AC 220V ±10% 50Hz |
Dimension | 640 × 630 × 590 mm |
Weight | 78 kg |
Employed in food, textile, plastic, geological, metallurgical, coal, biological medicine, petroleum chemical industry, environmental monitoring, sewage treatment, battery manufacturing, cosmetics, etc.
Labnics Microwave Digestion Systems utilize advanced microwave heating technology for faster sample digestion. These units are equipped with durable vessels resistant to harsh conditions, ensuring long-lasting performance. They continuously display pressure and temperature for each vessel, providing accurate control throughout the process. Our Digestion Systems allow users to adjust key parameters for flexibility in the operation.
Sample capacity | 20 |
Digestion tube volume | 300ml |
Digestion tube diameter | 42 mm |
Heating module | PID temperature control |
Sample capacity | 6 |
Digestion tube volume | 50 ml |
Digestion tube diameter | 32 mm |
Digestion tube height | 60 mm |
Sample capacity | 12 |
Digestion tube volume | 50 ml |
Digestion tube diameter | 32 mm |
Digestion tube height | 60 mm |
Sample capacity | 24 |
Digestion tube volume | 50 ml |
Digestion tube diameter | 32 mm |
Digestion tube height | 60 mm |
Sample capacity | 36 |
Digestion tube volume | 50 ml |
Digestion tube diameter | 32 mm |
Digestion tube height | 60 mm |
Sample capacity | 48 |
Digestion tube volume | 50 ml |
Digestion tube diameter | 32 mm |
Digestion tube height | 60 mm |
Sample capacity | 60 |
Digestion tube volume | 50 ml |
Digestion tube diameter | 32 mm |
Digestion tube height | 60 mm |
Sample capacity | 4 |
Heating module | Infrared |
Control mode | Digital |
Temperature range | Room temperature - 600 °C |
Sample capacity | 8 |
Heating module | Infrared |
Control mode | Digital |
Temperature range | Room temperature - 600 °C |
Sample capacity | 20 |
Heating module | Infrared |
Control mode | Digital |
Temperature range | Room temperature - 600 °C |