Let's Chat

Any Query ?

Gas Chromatography Mass Spectrometry NGMS-100

Gas Chromatography Mass spectrometry NGMS-100

Gas Chromatography Mass Spectrometry NGMS-100

Gas Chromatography Mass spectrometry NGMS-100 features a maximum inlet temperature of 450°C for efficient sample vaporization and accurate results. It is equipped with an electronic pressure flow control system for precise regulation and consistent flow rates. Our unit includes a high-energy dynode electron multiplier for improved sensitivity and detection of trace analytes. It has full-scale gauges for real-time monitoring of vacuum levels.

Specifications
GC Inlet Temperature Maximum 450°C
GC Pressure Range 0 to 100 psi
± 0.002psi
GC Pressure Control Mode Electronic Pressure Control (EPC), Support CV and CC
GC Split Mode Split/Splitless, Max. Split Ratio, 1000:1
GC Column Oven Working Temperature Room Temperature 4°C to 450 °C
GC Heating Rate Up to 120 °C/min
GC Temperature Programing 7 Stages/8 Platforms
MS EI Source Ionization Energy 5 W to 250 W, V (Adjustable)
MS Mass Range 1.5 to 1000 amu
MS Resolution Unit Resolution(Full width at half maximum)
MS Ion Source Temperature 100 to 3500 °C
MS Filament Emission Current 0 to 350 pA
GC-MS Interface Temperature Maximum 450 °C
MS Stability ± 0.10 amu/48 hrs
MS Sensitivity Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS)
MS Scan rate Up to l000 amu/s
MS Vacuum Turbo molecular pump(67L/s)
MS Detector High energy dynode electron multiplier
Power 220V
Dimension 720 × 620 × 820 mm
Net Weight 100 kg
Gross Weight 170 kg
Features
Applications

Gas Chromatography Mass Spectrometry identifies and quantifies chemical compounds by separating and analyzing them. It is used in environmental analysis, pharmaceuticals, and forensic science.

Standard Accessories

Mechanical Pump × 1 pc


GC-MS Column × 1 pc
Network Cable × 3 pcs
Series Port Cable × 1 pc
Power Cord × 2 pcs
Connection Cord × 1 pc
Sylphon Bellows (1 Meter)
Clamping Rings × 2 pcs
Seal × 2 pcs
Wrench × 3 pcs
Tweezers × 1 pc
Cross Screwdriver × 2 pcs
Straight Screwdriver × 1 pc
Monkey Wrench × 1 pc
Allen Wrench × 1 pc
Sleeve × 1 pc
15% Graphite /85% Vespel × 10 pcs
Syringe × 1 pc
Column Cutter × 1 pc
Liner × 1 pc
Fuse × 2 pcs
Sylphon Bellows (1.5 Meter)
Sylphon Bellows Connector × 1 pc
Hose clamps × 1 pc
Ion Source Holder × 1 pc
Column Mounting Jig × 1 pc
Stainless Steel Tube (7 Meter)
1/8"Ferrule1/8” × 1 pc
Valve Connector × 2 pcs
O-ringO × 11 pcs
Glass Wool × 1 pc
Front Ferrule × 3 pcs
Back Ferrule × 3 pcs
Injection port Wrench × 1 pc
Glass Liner × 1 pc
Moisture Trap × 1 pc
Oxygen Trap × 1 pc
Trap Bracket × 1 pc
Ties × 8 pcs
Mechanical pump outlet joint × 2 pcs
Adapter × 1 pc
Ethernet switch × 1 pc
Injection Septum × 1 pc

Optional Accessories

Auto Sampler

Buy Now

Gas Chromatography NGC-100

GC Inlet Temperature 450°C
GC Pressure Range 0 to 100 psi, ± 0.002psi
GC Pressure Control Mode Electronic Pressure Control (EPC), Support CV and CC
GC Split Mode Split/Splitless, Max. Split Ratio, 1000:1

Gas Chromatography NGC-101

Sample Introduction System Sample Injector and Evaporation Chamber
Control System Flow rate 200 ml/min (N2), 1000 ml/min (He)
Flow rate accuracy ± 5%
Flow rate repeatability ± 0.35%