Labnics Cart
0
Oops!
You can not compare more than 4 products

View catalogs for:

  • Crude Fibre Analyzer
  • Halogen Moisture Analyzer
  • Nitrogen Analyzer
  • Total Fat Analyzer
Automatic Kjeldahl Analyzer NAKN-100
Measure range 0.1 ~ 240 mg N
Recovery rate ≥ 99.5 %
Reproducibility ± 0.5 %
Analysis time 3 ~ 8 min/sample
Get quote
Automatic Soxhlet Extraction Apparatus NASE-100
Temperature range RT ± 5°C ~ 300°C
Measuring range 0.1 ~ 100%
Temperature accuracy ± 1°C
Sample weight 0.5g ~ 15g
Get quote
Fibre Analyzer NFA-100
Measuring range 0.1 % - 100 %
Sample weight 0.5 g - 3 g
Repeatability error Raw Fibre Content below 10% - ≤ 0.4% ; Raw Fibre Content above 10% - ≤ 1%
Capacity 6 samples / batch
Get quote
Halogen Moisture Analyzer NHMA-100
Capacity 110 g / 10 mg
Readability 0.01 g / 10 mg
Temperature range 40°C - 199°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-101
Capacity 110 g / 5 mg
Readability 0.005 g / 5 mg
Temperature range 40°C - 199°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-102
Capacity 110 g / 2 mg
Readability 0.002 g / 2 mg
Temperature range 40°C - 199°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-103
Capacity 110 g / 1 mg
Readability 0.001 g / 1 mg
Temperature range 40°C - 199°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-104
Capacity 110 g / 1 mg
Readability 0.001 g / 1 mg
Temperature range 40°C - 199°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-105
Capacity 200 g / 1 mg
Readability 0.001 g / 1 mg
Temperature range 40°C - 199°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-106
Capacity 110 g
Readability 0.001 g / 1 mg
Temperature range 40°C - 230°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-107
Capacity 110 g
Readability 0.001 g / 1 mg
Temperature range 40°C - 230°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-108
Capacity 210 g
Readability 0.001 g / 1 mg
Temperature range 40°C - 230°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-109
Capacity 210 g
Readability 0.001 g / 1 mg
Temperature range 40°C - 230°C
Operating temperature 5°C - 35°C
Get quote
Halogen Moisture Analyzer NHMA-111
Capacity 20g / 50g / 100g
Readability 0.001 g / 1 mg
Temperature range 60~160°C
Operating temperature 5°C - 35°C
Get quote
Semi-Automatic Kjeldahl Analyzer NSKN-100
Measure range 0.1~ 200 mg of N
Recovery rate ≥ 99 %
Reproducibility ± 1 %
Analysis time 5 ~ 10min/sample
Get quote
Semi-Automatic Kjeldahl Analyzer NSKN-101
Measure range 0.1~ 240 mg of N
Recovery rate ≥ 99 %
Reproducibility ± 1 %
Analysis time 5 ~ 10min/sample
Get quote
Semi-Automatic Kjeldahl Analyzer NSKN-102
Measure range 0.1~ 240 mg of N
Recovery rate ≥ 99 %
Reproducibility ± 1 %
Analysis time 5 ~ 10min/sample