Let's Chat

Any Query ?

Bench-top Conductivity Meter NBCM-100

Bench-top conductivity meter NBCM-100

Bench-top Conductivity Meter NBCM-100

Bench-top conductivity meter NBCM-100 is a bench-top device, protected with IP54 waterproof protection. It is used to measure multiple parameters like conductivity, temperature, resistivity, TDS, and salinity of a solution. Calibration with standard recognition for precise measurements. Automatic/Manual temperature compensation ensures accuracy of the results obtained.

Specifications
Parameters Conductivity, Temperature, Resistivity, TDS, and Salinity
Conductivity mode
Range 0.000 µS/cm to 3000 mS/cm
Resolution 0.001 µS/cm minimum, changes with ranges
Accuracy ± 0.5% FS
Reference Temperature 5, 10, 15, 18, 20, 25 ºC
Calibration Points Up to 5
Standard Recognition 146.5 µS/cm, 1408 µS/cm, 12.85 mS/cm, 111.3 mS/cm
Resistivity Mode
Range 5.00 Ω ·cm to 100.00 M Ω ·cm
Resolution 0.01 Ω ·cm minimum
Accuracy ± 0.5% FS
TDS Mode
Range 0.000 mg/L to 1000 g/L
Resolution 0.001 ppm minimum, changes with range
Accuracy ±0.5% FS
Salinity Mode
Type NaCl %
Range 0.00 to 8.00 %
Resolution 0.01%
Accuracy ± 0.1%
Temperature Mode
Range -5 to 130 ºC
Unit ºC
Resolution 0.1
Accuracy ± 0.1
Measurement
Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temperature Compensation ATC, MTC
Data
Data Storage 1000 Groups for each parameter
GLP Features Yes
Log Management Yes
Inputs
Temp. Probe 6 pin Mini DIN
Conductivity Probe 8 pin Mini DIN
Outputs
USB, RS 232 USB 2.0 flash memory device, printer, PC
Display options
Backlight Yes
Auto Shutdown 1 to 60 min, off
IP Rating IP54
Date and Time Yes
Power AC Adapter, 100-240 V AC input, DC 24 V output
Dimensions 280 × 280 × 130 mm
Weight 2500 g
Features
Applications

Bench-top conductivity meter is widely used across industries like environmental monitoring, water quality analysis, pharmaceuticals, food, and chemical research.

Buy Now

BOD Meter NBOD-102

Measurement range 0-4000mg/L
Measuring error ±10%
Cycle length 5 days
Measure amount 6

BOD Meter NBOD-101

Measuring range 0 to 4000 mg/L
Measuring error ±10%
Resolution 2 mg/L
Cycle length 1-5 days
BOD Meter NBOD-100
Measurement range 0 to 4000mg/L
Measuring error ±10%
Cycle length 5days
Measure amount 6

COD Analyzer NCA-100

High COD Range 20 to 10000mg/L
Low COD Range 2 to 150mg/L
Accuracy for COD < 50mg/L ≤ ±5%
Accuracy for COD > 50mg/L ≤ ±3%

Benchtop COD Digester NBCD-100

Digestion capacity 9 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 100 mm
Digestion temperature 20°C - 200°C
Benchtop COD Digester NBCD-101
Digestion capacity 16 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 150 mm / ф20mm × 150 mm
Digestion temperature 45°C - 190°C

Conductivity Controller Analyzer NCCA-100

Model no NCCA-100
Measuring range k= 1 0~2000μS/cm
Resolution 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm
Accuracy ± 2.0 %(FS)

Portable Conductivity Meter NCM-100

Conductivity specifications:- Conductivity range 0.000µS/cm ~ 1000mS/cm
Conductivity resolution 0.001µS/cm
Conductivity accuracy ± 1.0% (FS)
Resistivity specifications:- Resistivity range 5.00Ωcm~ 100.0MΩcm

Benchtop Dissolved Oxygen Meter NDOM-100
Dissolved Oxygen Range 0.00-20.00mg/L
Dissolved Accuracy ±0.2mg/L
Dissolved Resolution 0.01 mg/L
Saturation of Oxygen Range 0.0-200.0%

Dissolved Oxygen Sensor NOS-100

Dissolved Oxygen Range 0~20 mg/L or 0~200 %
Dissolved Oxygen Sensor Optical DO sensor
Dissolved Oxygen Accuracy 0.01
Dissolved Oxygen Sensor Drift <1 % per year

Dissolved Oxygen Sensor NOS-101

Dissolved Oxygen Range 0 to 20mg/L or 0 to 200%
Sensor Optical DO sensor
DO Accuracy 0.03
Dissolved Oxygen Sensor Drift <1% per year

Portable Fluoride Analyzer NPFA-100
Ion Concentration
Range 0.02 to 1900 ppm
Resolution 0.001, 0.01, 0.1, 1, automatic
Accuracy ±0.5% F.S
Calibration Points 2 to 5 points
Calibration Solutions 0.001 / 0.01 / 0.1 / 1 / 10 / 100 /1000/10000
Measurements Units ppm, mg/L, mol/L, mmol/L
mV
Range (-1999.9 to 1999.9) mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Temperature
Range 0 to 105°C / 32 to 221°F
Resolution 0.1°C/°F
Accuracy ±0.5°C / ±0.9°F
Offset Calibration 1 point
Calibration Range Reading ±10°C/°F
Other
Temperature Compensation 0 to 100°C / 32 to 212°F, manual or automatic
Hold Function Manual / Auto-read measurement endpoint
Stability Criteria Low / High
Calibration Due Alarm 1 to 31 days or off
Auto-Power Off 10 / 20 / 30 minutes after last key pressed
Memory Stores up to 500 data sets
Output USB communication interface
Connector BNC, 3.5 mm jack socket
Display Custom LCD (80 × 60 mm)
Power Supply 3 × 1.5V AA batteries or 5V DC power adapter
Battery Life Approximately 150 hours without backlight
Environmental Conditions 0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions 170 × 85 × 30 mm
Weight 300g

Labnics Benchtop Multi-Parameter Meter offers both automatic and manual temperature compensation, ensuring precise measurements. They include data analysis functions for detailed examination and interpretation of results. Our units include a touchscreen for simple and intuitive operation. These meters feature automatic electrode diagnosis to continuously monitor electrode conditions. They offer a data storage function for saving and managing measurement records.

Benchtop Multi-Parameter Meter NBMM-100

pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points

Benchtop Multi-Parameter Meter NBMM-101

Test parameters pH, conductivity, temperature, salinity, TDS, and dissolved oxygen
pH Range -2.000 to 20.000 pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, Selectable
Benchtop Multi-Parameter Meter NBMM-102
Test Parameters pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal. /DO Saturation)
pH Range: -2.000 to 20.000 pH<br/> Resolution: 0.1, 0.01, 0.001 pH<br/> Accuracy: ±0.002 pH<br/> Calibration Points: Up to 6<br/> Standard Customization: Yes<br/> Calibration Reminder: Yes<br/> Slope Limit: Yes
Calibration Solutions NIST, GB, DIN, USA, MERK, JIS buffers
mV/ORP Range: -2000.00 to 2000.00 mV<br/> Resolution: 0.1, 0.01 mV<br/> Accuracy: reading whichever is greater<br/> Calibration Points: 1 custom point (relative mV) <br/> EH ORP Mode: Yes

Labnics Multiparameter Conductivity Meter are designed to measure multiple parameters for comprehensive analysis. They feature imported sensors and advanced optical system for precise measurement. They offer various conductivity ranges for accurate sample readings. They are constructed with durable materials to withstand harsh environments. Our meter is ideal for water quality analysis, environmental monitoring and industrial processes.

Portable Multiparameter Conductivity Meter NPMCM-100

pH
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Conductivity
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS
Range 0to100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)

Multiparameter Conductivity Meter NPMCM-200

Absorbance Detection Range 0 to 3Abs
Absorbance Resolution 0.001Abs
Optical Path Stability ≤ ±0.005Abs/30min
Operation Repeatability ≤ ±0.01Abs

Portable PH Conductivity Meter NPCM-100
pH Range 2.000~20.000 pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, selectable
Calibration Points 1 to 5 points

PH Controller Analyzer NPCA-100

Model no NPCA-100
Detection method Electrode method
Measuring range 0 ~ 14 pH; normal temperature (0 ~ 80 ℃)
Resolution 0.01ph

Benchtop PH Meter NBPM-201

pH measuring range 0.00 ~ 14.00 pH
pH resolution 0.01 pH
pH accuracy ± 0.01 pH
Temperature measuring range 0°C~100°C
Benchtop PH Meter NBPM-200
pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points

PH ORP Meter NPOM-100

Model name NPOM-100
Measuring Range -2.00~20.00pH
Display Resolution 0.01pH
Measurement Accuracy ± 0.01pH

Turbidity Meter NTM-100

Measurement range 0~1100 NTU, 0~275 EBC, 0~9999 ASBC
Measurement accuracy ±2% of reading (0~500 NTU), ±3% (501~1100 NTU)
Measurement resolution 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU)
Sample volume 30 ml
Turbidity Meter NTM-101
Turbidity Range 0.000 to 20.00 NTU, 20.01 to 200.0 NTU, 200 to 2000 NTU, 2001 to 4000 NTU
Accuracy ≤ ±6%
Resolution 0.01NTU, 0.1NTU, 1NTU
Repeatability ≤ 0.5%

Multi-Purpose PH Tester NMPT-100

pH Range (-1.00) to 15.00
pH Accuracy ±0.01
pH Calibration Points 1 to 3 points
pH Buffer Options pH 4.01/6.86/7.00/9.18/10.01

Multi-Parameter Water Quality Analyzer NMWA-100

COD Measurement Range 0-15000mg/L
Ammonia Nitrogen Measurement Range 0-160mg/L
Phosphorus Measurement Range 0-100mg/L
Nitrogen Measurement Range 0-150mg/L

Online Ion Meter NOIM-100
Measurement Range 0 to 35500mg/L(ppm)
Measurement Principle Ion electrode method
Resolution 0.01mg/L(ppm)
Basic Error ± 2.5%

Labnics Online Ozone Meter detects ozone levels accurately across a wide range of concentrations. They include manual and automatic temperature compensation modes for reliable results. These ozone meter comes with built-in alarm functions for immediate alerts on fluctuating values. They enable efficient and reliable data transfer, ensuring smooth integration with other systems. Our units feature a large screen display for clear and easy interpretation of results.

Online Ozone Meter NOOM-100

Measurement Range 0 to 20mg/L<br/> 0 to 20 ppm
Measurement Principle Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic Error ±1%F. S

Labnics Digital pH Meter includes 3-point calibration to ensure reliable and consistent pH measurements. They include a digital pH sensor for obtaining precise results. The replaceable pH electrode allows to change of the degraded electrode for easy maintenance. Their stable operation enhances to function without fluctuations, assuring accurate data. Our Digital pH Meter eliminates vibrations, for precise readings by minimizing errors.

Digital PH Meter NDPM-100
pH Range 0.00 to 14.00 pH
pH Accuracy ± 0.01 pH
pH Resolution 0.01 pH
Calibration Points Three points (4.00, 6.86, 9.18)