Chromatography Instrument

Automatic Fraction Collector NAFC-100
Automatic Fraction Collector NAFC-100
Tube quantity 100
Maximum capacity 12ml
Time set 1 second to 24 hours
Display LED
Get quote
Gas Chromatography NGC-100
Gas Chromatography NGC-100
Display EPC (electronic pneumatic control) 7-inch touch screen display
Sample Introduction System sample injector and evaporation chamber
Column Oven
Temperature range Ambient temperature +7℃ ~ 420℃ (in 1℃ increment)
Temperature accuracy ± 0.02℃
Cooling time 350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting 0.1℃~80℃/min (in 1℃ increment)
Program ramps 20 ramps in total (99 ramps available with control workstation)
Size (L × W × H) 284 × 280 × 241mm (inside), 340 × 345 × 281mm (outside)
Flame Ionization Detector (FID)
Detection limit ≤8×10-12(n-hexadecane)
Drift ≤1.5×10-13A/h
Noise ≤3×10-14A/h
Linearity range ≥106
Get quote
Gas Chromatography NGC-101
Gas Chromatography NGC-101
Sample Introduction System Sample Injector and Evaporation Chamber
Column Oven
Temperature range Ambient temperature +7℃ to 400℃(in 1°C increment)
Temperature accuracy ± 0.02°C
Cooling time 350℃ to 100℃ ≤3 min, 400°C to 50°C in 8-10 min at 25℃ ambient
Programmed temperature setting 0.1°C to 80°C/min (in 1°C increment)
Program ramps 20 ramps in total (99 ramps available with control workstation)
External Size (L × W × H) 340 × 345 ×281 mm
Internal Size 284 × 280 ×241 mm
Flame ionization detector (FID)
Detection limit ≤8×10-12g/s(n-hexadecane)
Drift ≤1.5×1013 A/h
Noise ≤3×10 -14 A
Linearity range ≥106
Thermal Conductivity Detector(TCD)
Maximum Temperature 400 ℃
Temperature control accuracy ±0.1℃
Sensitivity ≥10000 mV, mL/mg (n-hexadecane)
Drift ≤100 µV/30 min (after the instrument is stable for 2 hours)
Baseline noise ≤20 µ V
Linearity range ≥104
Get quote
Gas Chromatography Mass spectrometry NGMS-100
Gas Chromatography Mass Spectrometry NGMS-100
For GC
Inlet temperature Max. 450°C
Pressure range 0 to 100psi, ±0.002psi
Pressure control mode Electronic pressure control (EPC), support CV and CC
Split mode Split/splitless, max. split ratio: 1000:1
Column oven working temperature Room temperature+4°C to 450°C
Heating rate Up to 120°C/min
Temperature programming 7 stages/ 8 platforms
Auto Sampler Optional
For MS
EI source ionization energy 5W to 250,V (Adjustable)
Mass range 1.5~1000 amu
Resolution Unit resolution (full width at half maximum)
Ion source temperature 100 to 3500
Filament emission current 0-350 pA
GC-MS Interface temperature Max. 450°C
Stability ±0.10 amu/48 hrs
Sensitivity Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS)
Scan rate Up to l000 amu/s
Vacuum Turbo molecular pump(67L/s)
Detector High energy dynode electron multiplier
Get quote
Gradient High-performance Liquid Chromatography NHLC-100
Gradient High-performance Liquid Chromatography NHLC-100
High pressure pump 2
Column C18
Column dimension 250cm×4.6cm
Injection valve 6-way ,7725i
Get quote
Isocratic High-performance Liquid Chromatography NHLC-200
Isocratic High-performance Liquid Chromatography NHLC-200
High pressure pump 1
Column C18
Column dimension 250cm×4.6cm
Injection valve 6-way ,7725i
Get quote
Quaternary High Pressure Liquid Chromatography NHLC-300
Quaternary High Pressure Liquid Chromatography NHLC-300
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Quaternary High Pressure Liquid Chromatography NHLC-301
Quaternary High Pressure Liquid Chromatography NHLC-301
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Quaternary High Pressure Liquid Chromatography NHLC-302
Quaternary High Pressure Liquid Chromatography NHLC-302
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Quaternary High Pressure Liquid Chromatography NHLC-303
Quaternary High Pressure Liquid Chromatography NHLC-303
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Liquid Chromatograph Mass Spectrometer NLMS-100
Liquid Chromatograph Mass Spectrometer NLMS-100
Mass range (m/z) 10-1500
Resolution unit resolution (FWHM ≤ 0.7amu)
Mass accuracy ±0.20 amu (in the mass calibration range of scan mode)
Mass axis stability 0.20 amu/12h (under constant temp. of ± 2℃)
Get quote
Vacuum-Type Glass Filtration Unit NVGF-103
Vacuum-Type Glass Filtration Unit NVGF-103
Pore Size of Filter 20 µm
Receiving Bottle 1000 ml
Material Glass
Funnel 300 ml
Get quote
Vacuum-Type Multiple Filtration Unit NVMF-102
Vacuum-Type Multiple Filtration Unit NVMF-102
Filter head 6
Funnel valve SS 316L
Support screen SS 316L
Funnel capacity 300 ml
Get quote