Chromatography Instrument
Chromatography Accessories
Gas Chromatography
Liquid Chromatography
COMPARE
Automatic Fraction Collector NAFC-100
Tube quantity
100
Maximum capacity
12ml
Time set
1 second to 24 hours
Display
LED
Get quote
Compare
Gas Chromatography NGC-100
Display
EPC (electronic pneumatic control) 7-inch touch screen display
Sample Introduction System
sample injector and evaporation chamber
Column Oven
Temperature range
Ambient temperature +7℃ ~ 420℃ (in 1℃ increment)
Temperature accuracy
± 0.02℃
Cooling time
350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting
0.1℃~80℃/min (in 1℃ increment)
Program ramps
20 ramps in total (99 ramps available with control workstation)
Size (L × W × H)
284 × 280 × 241mm (inside), 340 × 345 × 281mm (outside)
Flame Ionization Detector (FID)
Detection limit
≤8×10
-12
(n-hexadecane)
Drift
≤1.5×10
-13
A/h
Noise
≤3×10
-14
A/h
Linearity range
≥10
6
Get quote
Compare
Gas Chromatography NGC-101
Sample Introduction System
Sample Injector and Evaporation Chamber
Column Oven
Temperature range
Ambient temperature +7℃ to 400℃(in 1°C increment)
Temperature accuracy
± 0.02°C
Cooling time
350℃ to 100℃ ≤3 min, 400°C to 50°C in 8-10 min at 25℃ ambient
Programmed temperature setting
0.1°C to 80°C/min (in 1°C increment)
Program ramps
20 ramps in total (99 ramps available with control workstation)
External Size (L × W × H)
340 × 345 ×281 mm
Internal Size
284 × 280 ×241 mm
Flame ionization detector (FID)
Detection limit
≤8×10-12g/s(n-hexadecane)
Drift
≤1.5×1013 A/h
Noise
≤3×10 -14 A
Linearity range
≥106
Thermal Conductivity Detector(TCD)
Maximum Temperature
400 ℃
Temperature control accuracy
±0.1℃
Sensitivity
≥10000 mV, mL/mg (n-hexadecane)
Drift
≤100 µV/30 min (after the instrument is stable for 2 hours)
Baseline noise
≤20 µ V
Linearity range
≥104
Get quote
Compare
Gas Chromatography Mass Spectrometry NGMS-100
For GC
Inlet temperature
Max. 450°C
Pressure range
0 to 100psi, ±0.002psi
Pressure control mode
Electronic pressure control (EPC), support CV and CC
Split mode
Split/splitless, max. split ratio: 1000:1
Column oven working temperature
Room temperature+4°C to 450°C
Heating rate
Up to 120°C/min
Temperature programming
7 stages/ 8 platforms
Auto Sampler
Optional
For MS
EI source ionization energy
5W to 250,V (Adjustable)
Mass range
1.5~1000 amu
Resolution
Unit resolution (full width at half maximum)
Ion source temperature
100 to 3500
Filament emission current
0-350 pA
GC-MS Interface temperature
Max. 450°C
Stability
±0.10 amu/48 hrs
Sensitivity
Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS)
Scan rate
Up to l000 amu/s
Vacuum
Turbo molecular pump(67L/s)
Detector
High energy dynode electron multiplier
Get quote
Compare
Gradient High-performance Liquid Chromatography NHLC-100
High pressure pump
2
Column
C18
Column dimension
250cm×4.6cm
Injection valve
6-way ,7725i
Get quote
Compare
Isocratic High-performance Liquid Chromatography NHLC-200
High pressure pump
1
Column
C18
Column dimension
250cm×4.6cm
Injection valve
6-way ,7725i
Get quote
Compare
Quaternary High Pressure Liquid Chromatography NHLC-300
Quaternary Pump Specifications:- Flow rate Range
0.001-10.000mL/min, 0.001mL increments
Flow accuracy
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision
RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure
50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Compare
Quaternary High Pressure Liquid Chromatography NHLC-301
Quaternary Pump Specifications:- Flow rate Range
0.001-10.000mL/min, 0.001mL increments
Flow accuracy
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision
RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure
50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Compare
Quaternary High Pressure Liquid Chromatography NHLC-302
Quaternary Pump Specifications:- Flow rate Range
0.001-10.000mL/min, 0.001mL increments
Flow accuracy
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision
RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure
50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Compare
Quaternary High Pressure Liquid Chromatography NHLC-303
Quaternary Pump Specifications:- Flow rate Range
0.001-10.000mL/min, 0.001mL increments
Flow accuracy
≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision
RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure
50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Get quote
Compare
Liquid Chromatograph Mass Spectrometer NLMS-100
Mass range (m/z)
10-1500
Resolution
unit resolution (FWHM ≤ 0.7amu)
Mass accuracy
±0.20 amu (in the mass calibration range of scan mode)
Mass axis stability
0.20 amu/12h (under constant temp. of ± 2℃)
Get quote
Compare
Vacuum-Type Glass Filtration Unit NVGF-103
Pore Size of Filter
20 µm
Receiving Bottle
1000 ml
Material
Glass
Funnel
300 ml
Get quote
Compare
Vacuum-Type Multiple Filtration Unit NVMF-102
Filter head
6
Funnel valve
SS 316L
Support screen
SS 316L
Funnel capacity
300 ml
Get quote
Compare
Hello
×
Suggested Products
Gas Chromatography NGC-101
Vacuum-Type Multiple Filtration Unit NVMF-102
Liquid Chromatograph Mass Spectrometer NLMS-100
Automatic Fraction Collector NAFC-100
Quaternary High Pressure Liquid Chromatography NHLC-300