Benchtop Multi-Parameter Meter NBMM-100
Benchtop Multi-Parameter Meter NBMM-100
pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Get quote
Benchtop Multi-Parameter Meter NBMM-101
Benchtop Multi-Parameter Meter NBMM-101
pH Specifications:- Range (-2.000~20.000) pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, Selectable
pH Calibration Points 1 to 5 points
Get quote
Portable Fluoride Analyzer NPFA-100
Portable Fluoride Analyzer NPFA-100
Ion Concentration
Range 0.02 to 1900 ppm
Resolution 0.001, 0.01, 0.1, 1, automatic
Accuracy ±0.5% F.S
Calibration Points 2 to 5 points
Calibration Solutions 0.001 / 0.01 / 0.1 / 1 / 10 / 100 /1000/10000
Measurements Units ppm, mg/L, mol/L, mmol/L
mV
Range (-1999.9 to 1999.9) mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Temperature
Range 0 to 105°C / 32 to 221°F
Resolution 0.1°C/°F
Accuracy ±0.5°C / ±0.9°F
Offset Calibration 1 point
Calibration Range Reading ±10°C/°F
Other
Temperature Compensation 0 to 100°C / 32 to 212°F, manual or automatic
Hold Function Manual / Auto-read measurement endpoint
Stability Criteria Low / High
Calibration Due Alarm 1 to 31 days or off
Auto-Power Off 10 / 20 / 30 minutes after last key pressed
Memory Stores up to 500 data sets
Output USB communication interface
Connector BNC, 3.5 mm jack socket
Display Custom LCD (80 × 60 mm)
Power Supply 3 × 1.5V AA batteries or 5V DC power adapter
Battery Life Approximately 150 hours without backlight
Environmental Conditions 0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions 170 × 85 × 30 mm
Weight 300g
Get quote
Portable Multiparameter Conductivity Meter NPMCM-100
Portable Multiparameter Conductivity Meter NPMCM-100
pH
Range -2.000~20.000pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
Compensation Mode Manual or Automatic
mV
Range -1999.9~1999.9mV
Accuracy ±0.2mV
Resolution 0.1, 1mV, Selectable
Conductivity
Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10 or User-defined
Normalization Temperature 20°C or 25°C
TDS
Range 0to100ppt (Max. 200ppt, depending on factor setting)
Accuracy ±1% F.S
TDS Factor 0.1~1.0 (Default 0.5)
Get quote