Let's Chat

Any Query ?

Atomic Absorption Spectrophotometer NAAS-100

Atomic Absorption Spectrophotometer NAAS-100

Atomic Absorption Spectrophotometer NAAS-100

Atomic Absorption Spectrophotometer NAAS-100 is an analytical instrument that helps in the quantification of trace metal elements on their basis of spectral activity in gaseous states of the test under study. It is a microprocessor-controlled system with an RS232 interface that effectively controls fuel gas of burner and automatic positioning and optimization of each 8 hollow cathode lamp turret. It is equipped with an advanced graphite furnace with rapid heating and analysis of a sample that retains the accuracy of the instrument. The audible sound alarm system effectively monitors flame conditions and ensures the safety of instruments as well as of the user.

Specifications

Optical System specifications:- Wavelength Range 190nm - 900nm
Grating Groove 1800/mm
Spectral Bandwidth 0.1nm/0.2nm/0.5nm/1.0nm/2.0nm
Wavelength Accuracy ± 0.25nm
Wavelength Reproducibility ≤ 0.15nm
Wavelength Resolution 0.2nm ± 0.02nm
Baseline Stability ± 0.004Abs/30min
Background Correction Deuterium Arc 1.0Abs Self Reversal 1.0Abs
Light Source 8 hollow cathode lamp turret, automatic alignment
Flame Analysis Specifications:- Flame Type Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)
Characteristic Concentration of Flame Cu<0.04μg/ml1% (Air/Acetylene) Ba<0.15μg/mL/1%(Nitrous Oxide/Acetylene)
Detection Limit of Flame Cu ≤ 0.006μg/ml
Flame Burner material Titanium Metal Alloy
Repeatability of Flame analysis Cu <1.0%(air – acetylene method) Ba< 1.0% (air – acetylene method)
Sensitivity of Flame analysis Cu 2ug/ml
Absorption of Flame analysis >0.28Abs
Graphite Furnace Analysis Specifications:- Temperature Range Ambient to 2650°C
Detection Limit of Graphite Furnace Cd≤ 0 .01ng/ml
Repeatability of Graphite Furnace Cu < 3%, Cd < 4%
Temperature Control Precision of Graphite Furnace < 1%
Background Correction of Graphite Furnace > 55 times
Dimensions (L×D×H) 1100 × 500 × 450mm
Weight 75kg

Features

  • Czerny-Turner Monochromatic grating system
  • Nebulizer High-efficiency glass nebulizer
  • Corrosion resistant material used for Atomization chamber
  • Flame off button for auto safety precautions
  • A sensor monitors the level of liquid
  • Temperature Control Voltage feedback control on drying and ashing
  • Multi-Standard Calibration, Standard Addition, and Interpolation etc

Applications

It has multidisciplinary applications in field of science for quantitative and qualitative analysis for test samples like blood, serum, food samples, petrochemical etc. It is commonly used in field of food, agriculture, geology, Clinical, Environmental, Mining and Pharmaceutical etc.

Optional Accessories

Accessories No Name
1 Acid proof glass nebulizer
2 Hydride generator
3 AAS Flame autosampler
4 Graphite furnace autosampler

Get Quote