labnics-cart
0
Oops!
You can not compare more than 4 products

View catalogs for:

  • Documentation System
  • Dry Bath Incubators
  • Electrophoresis
  • Hybridization Incubator
  • Thermal Cyclers
Dry Bath Incubator NDBI-100
Temperature range + 5 ℃ - 150 ℃
Heating time ≤ 30min (20 ℃ - 150 ℃)
Cooling time
Temperature stability at 100 °C – 150 ℃ ≤ ± 1 ℃
Get quote
Dry Bath Incubator NDBI-101
Temperature range -10 °C ~ + 100 °C
Heating time ≤ 15min (20 ℃ ~ + 100 ℃)
Cooling time ≤ 30 mins
Temperature stability at 100 °C – 150 ℃
Get quote
Gel Documentation System NGDS-100
Effective pixels 2560×1920
Pixel density 10 bits
Pixel size 5.4×5.4 um
Resolution 5.0 megapixels
Get quote
Gradient Thermal Cycler NGTC-102
PCR Type Gradient
Capacity Double 48×0.2ml
Temperature Range 0°C ~100°C
Heating Rate 5°C /s
Get quote
Gradient Thermal Cycler NGTC-200
PCR Type Gradient
Capacity 96 × 0.2 ml
Temperature Range 0°C ~105°C
Heating Rate 5°C /s
Get quote
Gradient Thermal Cycler NGTC-201
PCR Type Gradient
Capacity 6 × 16 × 0.2 ml
Temperature Range 0°C ~105°C
Heating Rate 5°C /s
Get quote
Gradient Thermal Cycler NGTC-202
PCR Type Gradient
Capacity 96 × 0.2 ml
Temperature Range 0°C ~105°C
Heating Rate 5°C /s
Get quote
Horizontal Electrophoresis System NHES-103
Gel Trays (W×L) 200 x 200 mm, 200 x 150 mm, 200 x 100 mm
Buffer volume 1800 ml
Comb thickness 1 mm and 1.8 mm
Comb throughput 17, 22, 36, 44 samples
Get quote
Hybridization Incubator NHI-100
Sample capacity 6 hybrid tubes
Hybrid tube size 35 × 240 mm
Temperature range Ambient + 5°C - 100°C
Temperature Accuracy ± 0.5°C (at 37°C)
Get quote
Hybridization Incubator NHI-101
Sample capacity 6 hybrid tubes
Hybrid tube size 35 × 240 mm
Temperature range Ambient + 5°C - 100°C
Temperature Accuracy ± 0.5°C (at 37°C)
Get quote
Hybridization Incubator NHI-102
Sample capacity 6 hybrid tubes
Hybrid tube size 35 × 240 mm
Temperature range Ambient + 5°C - 100°C
Temperature Accuracy ± 0.5°C (at 37°C)
Get quote
Paper Electrophoresis Apparatus NPEA-100
Type of Electrophoresis Paper or Cellulose acetate membrane electrophoresis
Buffer volume about 1,000 ml
Voltage required 5V/cm of paper
Overall Dimensions (L×W×H) 370×270×110 mm
Get quote
Real Time Thermal Cycler NRTC-100
Sample capacity 0.1ml PCR tubes × 96, 8×12 PCR plate or 96 well plate ×1
Reaction volume 10-50 µl
Maximum Heating/Cooling rate 6 °C/s
Heating Temperature Range 4 °C - 100 °C
Get quote
Vertical Electrophoresis System NVES-200
Sample capacity Up to 32 samples
Number of gel slab 1 to 2 pcs
Gel dimension Standard configuration: 83×97 mm ; Optional configuration: 83×73 mm
Gel casting material Inspissate polycarbonate
Get quote
Vertical Electrophoresis System NVES-201
Sample capacity Nil
Number of gel slab 1 to 2 pcs
Gel dimension 95×110 mm
Gel casting material 800 ml
Get quote
Vertical Electrophoresis System NVES-202
Sample capacity Up to 48 samples
Number of gel slab 1 to 2 pcs
Buffer capacity 800 ml
Gel casting material Inspissate polycarbonate
Get quote
Vertical Electrophoresis System NVES-203
Gel area 345×300 mm
Sample capacity Up to 68 samples
Buffer volume Up to 1000 ml
Gel dimension 345×300 nm
Get quote