Let's Chat

Any Query ?

Analytical High-performance Liquid Chromatography NHLC-400

Analytical High-performance Liquid Chromatography NHLC-400

Analytical High-performance Liquid Chromatography NHLC-400

Analytical High-performance Liquid Chromatography NHLC-400 is an advanced, highly effective analytical HPLC system that includes a UV-Vis detector with a wavelength range of 190 to 700 nm, a DAD (Diode Array Detector) detector with a wavelength range of 190 to 800 nm, and a high-pressure constant flow pump and low-pressure quaternary constant flow pump with a flow range of 0.001 to 10.000 mL/min (step 0.001 mL/min). This HPLC system provides accurate, reliable results with improved working efficiency. Powerful software is integrated to regulate, capture, and analyze data, as well as manage the operation.

Specifications
High-Pressure Constant Flow Pump
Flow Range 0.001 to 10.000 mL/min (step 0.001 mL/min)
Accuracy ≤±0.2%
Precision ≤0.06% RSD
Pressure Range 0 to 45 MPa
Power AC 220 V±10%, 50 Hz/80 W
Dimension (L × W × H) 420 × 300 × 175 mm
Weight 12 kg
Low-Pressure Quaternary Constant Flow Pump
Flow Range 0.001 to 10.000 mL/min (step 0.001 mL/min)
Gradient Accuracy ≤±1%
Retention Time Repeatability ≤0.1%
Maximum Working Pressure 63 Mpa
Communication Methods UDP Network Communication
Mixed Volume 750μL
Power AC 220 V±10%, 50 Hz/100 W
Dimension (L × W × H) 400 × 300 × 180 mm 
Weight 15 kg
UV-Vis Detector
Linear 2.0 AU
Wavelength Range 190 to 700 nm
Noise ≤± 0.5,105 AU
Drift ≤1.0 × 104 AU/h
Cell Analytical: Optical path 10 mm, 11μL Semi-prep scale: Optical path 2 mm, 6μL
Power AC 220V±10%, 50 Hz/100 W
Dimension (L × W × H) 420 × 300 × 175 mm
Weight 16 kg
Diode Array Detector
Linear ≥2.0 AU
Wavelength Range 190 to 800 nm
Noise ≤±1.0M05 AU
Drift ≤2.0 × 104 AU/h
Power AC220 V±10%, 50 Hz/180 W
Dimension (L × W × H) 500 × 300 × 175 mm
Weight 18 kg
Column oven
Temperature Range Ambient +5°C to 85 °C
Accuracy ±0.3 °C
Precision ≤0.1 °C
Power AC220 V±10%, 50 Hz/130 W
Dimension (L × W × H) 420 × 300 × 120 mm
Weight 7kg
Other parameters
Pump P3100 × 2
Detector UV3100 × 1 
Gradient mixer TD-1-15 × 1 
Solvent bottle tray TP3100 × 1
Sample injector Rheodyne 7725i × 1
Column Supersil ODS2 5pm ID4.6 × 200mm × 1
Workstation W5100 × 1
Valve mounting frame ZJ-1 × 1
System kit EClassical 3100 × 1
Power AC220V±10%, 50Hz
Package size 600 × 440 × 380 mm × 3
Gross weight 45 kg
Features
Applications

It is widely used to separate and analyze a mixture of compounds in multidisciplinary fields like research and development studies, food science, environmental science for analysis and detection of impurities, ligand-exchange chromatography, high-pH anion-exchange chromatography of carbohydrates and oligosaccharides, water purification, pre-concentration of trace components, and ion-exchange chromatography of proteins

Optional Accessories

Column oven

Get Quote

Gradient High-performance Liquid Chromatography NHLC-100

High pressure pump 2
Column C18
Column dimension 250cm×4.6cm
Injection valve 6-way ,7725i

Isocratic High-performance Liquid Chromatography NHLC-200
High pressure pump 1
Column C18
Column dimension 250cm×4.6cm
Injection valve 6-way ,7725i

Quaternary High Pressure Liquid Chromatography NHLC-301

Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)

Quaternary High Pressure Liquid Chromatography NHLC-302

Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)

Quaternary High Pressure Liquid Chromatography NHLC-303

Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Quaternary High Pressure Liquid Chromatography NHLC-300
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)