| Atomic Absorption Spectrophotometers– LAAS Series |
|
 |
Wavelength Range–190-900nm
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A better than 30 times.
Lamp Turret– 6
more.. |
|
 |
Wavelength Range–190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A better than 30 times.
Lamp Turret–6
more.. |
|
 |
Wavelength Range–190-900nm
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
Lamp Turret–4
more.. |
|
 |
Wavelength Range–190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
Lamp Turret–6.
Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA.
Burner–10cm single slot all titanium burner for Air-C2H2 flame; 5cm single slot all titanium burner for oxygen rich flame.
more.. |
|
 |
Wavelength Range–190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
Lamp Turret–6.
Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA.
Burner–10cm single slot all titanium burner for Air-C2H2 flame.
more.. |
|
 |
Wavelength Range–190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
Lamp Turret–4.
Lamp Current Adjustment–Automatic adjustment and display.Wide pulse current: 0~25mA.
Burner–10cm single slot all titanium burner for Air-C2H2 flame.
more.. |
|
 |
Wavelength Range– 190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H background correction capability at 1.8A is better than 30 times.
Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)
more.. |
|
 |
Wavelength Range– 190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
Lamp Number– 2 lamps (one preheating).
Burner– 10cm single slot all titanium burner.
more..
|
|
| Atomic Emission Spectrophotometer–LAES-10 |
|
 |
Charge Capacitance– Pre-burn 7 µf, Expose 1.5 µf
Discharge Inductance– Pre-burn 35 µh; Expose 70µh
Spectrum Range– 175-450 nm
Optical Channels– up to 36 channels
Width of entrance slit– 20 µm
Width of exit slit– 50 µm, 75 µm
more.. |
|
| Atomic Fluorescence Spectrophotometer Environmental Protection Type– LAFS 100 |
|
 |
With "High efficiency Hg-elimination Technique.
Determination of Hg, As, Sb, Bi, Se, Te, Pb, Sn, Ge, Zn and Cd.
Quartz atomizer with "full-ceramics infrared heating temperature control" technique has super long lifetime.
Realize two or three elements determination simultaneously.
more.. |
|
| UV-Visible Spectrophotometers LUV Series |
|
 |
Optical System– Double Beam
Wavelength Range– 190 ~1100 nm
Spectral Bandwidth– 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
Detector– Silicon photo diode
Photometric Accuracy– ±0.3%T (0~100%T); ±0.002A (0~1A)
more.. |
|
 |
Optical System– Double Beam
Wavelength Range– 190~900nm
Spectral Bandwidth– 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
Detector– Photomultiplier
Photometric Accuracy– ± 0.3%T (0~100%T), ± 0.002A (0~0.5A), ± 0.004A (0.5A~1A)
more..
|
|
 |
Optical System– Single Beam
Wavelength Range– 190 - 1100nm
Spectral Bandwidth– 2nm (5nm, 4nm, 1nm, 0.5nm optional)
Detector– Silicon photodiode
Photometric Accuracy– 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
more.. |
|
 |
Optical System– Single Beam
Wavelength Range– 190 - 1100nm
Spectral Bandwidth– 2nm (5nm, 1nm optional)
Detector– Silicon photo-diode
Photometric Accuracy– 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
more.. |
|
 |
Wavelength Range– 190 - 1100 nm
Spectral Bandwidth– 5nm (1, 2, 4nm optional)
Detector– Silicon Photodiode
Photometric Accuracy– 0.5% T
more.. |
|
| Visible Spectrophotometer L-VIS–400 |
|
 |
Optical System– Single Beam
Wavelength Range– 320 - 1100nm
Spectral Bandwidth– 2.0nm (5nm, 1nm optional)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)
more.. |
|
| UV-VIS Split Beam Spectrophotometers - LUV 1000 Series |
|
 |
Optical System– Split Beam
Wavelength Range– 190–1100nm
Spectral Bandwidth– 2nm fixed slit
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
more..
|
|
 |
Optical System– Split Beam
Wavelength Range– 190–1100nm
Spectral Bandwidth– 0.5, 1, 2, 5nm (variable slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
more..
|
|
| UV- VIS Double Beam Spectrophotometers- LUV 1000 Series |
|
 |
Optical System– Double Beam
Wavelength Range– 190 – 1100nm
Spectral Bandwidth– 2nm (fixed slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
more..
|
|
 |
Optical System– Double Beam
Wavelength Range– 190 – 1100nm
Spectral Bandwidth– 0.5, 1, 2, 5nm (Variable slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
more..
|
|
| UV- VIS Double Beam Spectrophotometer- LUV 1000E |
|
 |
Optical System– Double Beam
Wavelength Range– 190 – 900nm
Spectral Bandwidth– 0.5, 1, 2, 5nm (Variable slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
more..
|
| |
|
| Optional Accessories for UV-VIS Spectrophotometers 1000 Series |
| • |
Specular reflection unit |
| • |
Automatic 8-cell holder |
| • |
Changeable Angles Solid Samples Cell Holder |
| • |
Solid sample cell holder |
| • |
Dual-Channels sipper pump |
| • |
Constant-temperature cell holder |
| • |
50mm Long-pathlength cell holder |
| • |
Short-pathlength cell holder |
| • |
Peltier thermoelectric cell holder |
| • |
Test Tube Holder |
| • |
Micro-cell holder |