
»
AA Spectrophotometer
»
AE Spectrophotometer
»
AF Spectrophotometer
»
Autoclave
»
Baths & Circulators
»
Bioreactor
»
Centrifuge
»
CO2 Incubator
»
Environmental Chamber
»
Freeze Dryer/Lyophilizer
»
Freezers
»
FTIR Spectrometer
»
Fume Hoods
»
Furnaces
»
Gel Documentation Systems
»
Ice Flakers
»
Incubators
»
Laminar Air Flow Chamber
»
Microplate Readers
»
Microplate Washer
»
Ovens
»
Particle Counter
»
Particle Image Processor
»
Particle Size Analyzer
»
PCR Real time
»
Pipettors
»
Plant Growth Chamber
»
Refractometer
»
Safety Cabinets
»
Shakers
»
Shaking Incubator
»
Spectrophotometer UV-Vis
»
Thermal Cyclers
»
Transilluminator
»
Water Analysis Systems
»
Water Purification System
»
X-Ray Spectrometer
|
 |
| |
- Don't expose the instrument to low / high temperature and sun light for long time, to avoid LCD losing effectiveness.
- Because the instrument is very precise, prevent it from violent shock.
- To avoid damage, don't disassemble and assemble the instrument or change the inner circuit and parts.
- Zero-setting should be implemented strictly according to instruction.
- Be sure to clean the prism surface and window of stage before and after every measurement.
- To avoid accuracy loss by evaporation, be sure to implement measurement immediately after dripping solution on
window of stage.
- It can cause wrong results if measured under low voltage.
- Don't use the instrument in a humid and corrosive environment.
- Prevent the liquid from entering into battery house.
- Don't use it under the strong light (as sunlight, lamp etc.).
|
Technical Specification:
- Temperature Measurement Range : 0°C -40°C
- Precision of Measurement Temperature : ±1°C
- Measurement Temperature Resolution : 1°C
- Operation Temperature : 0°C ~ 35°C
- Storage Temperature : 0°C ~ 50°C
- Dimension : 135 x 65 x 70mm
- Weight : 200g
- Power Supply : 1 x battery (9v)
- Operating Time : More than 1500 times per Battery
- Automatic Temperature Compensation
- Automatic Shut Off
- Conversion between Centigrade and Fahrenheit Degree
- Alarm of Low Voltage
|
|
| Model No. |
Application |
Range |
Accuracy |
Catalog No. |
| LDRM-10 A |
Brix |
0~35% |
0.1 |
50750801 |
| LDRM-10 B |
Brix
Refractive Index |
0~35%
1.3330~1.3900 |
0.1
0.0003 |
50750802 |
| LDRM-10 C |
Brix |
0~45% |
0.1 |
50750803 |
| LDRM-10 D |
Brix
Refractive Index |
0~45%
1.3330~1.4089 |
0.1
0.0003 |
50750804 |
| LDRM-10 E |
Brix |
28~65% |
0.1 |
50750805 |
| LDRM-10 F |
Brix
Refractive Index |
28~65%
1.3770~1.4535 |
0.1
0.0003 |
50750806 |
| LDRM-10 G |
Brix |
58~92% |
0.1 |
50750807 |
| LDRM-10 H |
Brix
Refractive Index |
58~92%
1.4370~1.5090 |
0.1
0.0003 |
50750808 |
| LDRM-10 I |
Salinity |
0~28% |
0.1 |
50750809 |
| LDRM-10 J |
Salinity
Refractive Index |
0~28%
1.3330~1.3900 |
0.1
0.0003 |
50750811 |
| LDRM-10 K |
Urine sp.g |
1.000~1.050 |
0.0001 |
50750812 |
| LDRM-10 L |
Urine Sp.G
Serum P.
Refractive Index |
1.000~1.050
0~12
1.3330~1.3900 |
0.0003
0.1
0.0003 |
50750813 |
| LDRM-10 M |
Mass s/w
Vol Ap
oe
kmw |
0~35%
0~22%
0~150
0~25 |
0.1
0.1
1
0.1 |
50750814 |
| LDRM-10 N |
Brix
Salinity
Refractive Index |
0~35%
0~28%
1.3330~1.3900
|
0.1
0.1
0.0003
|
50750815 |
|
|
 |
|
| |
|